Hatz H-series: innovation meets reliability A groundbreaking downsizing approach was adopted in the development of the Hatz H-series. The outcome are extremely compact, turbocharged engines that reach a maximum output of 64 kilowatts, setting benchmarks in their performance classes |
|||||||||||||||||||||||
. | 4H50N (i) |
||||||||||||||||||||||
Type | 4 - Stroke liquid-cooled diesel engine |
||||||||||||||||||||||
Aspiration | Turbo without charge air cooling |
Turbocharger with charge air cooling |
Natural aspiration |
Turbocharger with charge air cooling |
|||||||||||||||||||
Number of cylinders | 3 |
3 |
3 |
3 |
4 |
4 |
4 |
4 |
|||||||||||||||
Bore and stroke | mm | 84 x 88 |
|||||||||||||||||||||
Displacement | cc | 1454 |
1962 |
||||||||||||||||||||
Compression ratio | 17,5:1 |
||||||||||||||||||||||
Fuel | Diesel fuel (ASTM No. 2-D) |
||||||||||||||||||||||
Engine oil capacity (Max) | l | 5,00 |
9,00 |
7,00 |
|||||||||||||||||||
Dry weight basic engine | kg | 132 |
140 |
154 (ii) |
133 |
159 |
158 |
173 (ii) |
152 |
||||||||||||||
Condition |
R.P.M. |
Engine output max (kW / hp) |
|||||||||||||||||||||
Blocked ISO fuel stop power (IFN) for intermittent loading according to ISO 3046-1.6 Applies to variable speed. 3H50TICD | 3H50TIC Also available with 36.4 kW / 49.4 hp @ 2500 rpm for use in California without registration requirements. |
3000 rpm |
- |
- |
- |
44,2 / 59,2 |
- |
55,4 / 74,2 |
- |
55,0 / 73,7 |
||||||||||||||
2800 rpm |
18,4 / 24,7 |
43,7 / 59,6 |
43,6 / 58,4 |
43,6 / 58,4 |
- |
55,4 / 74,2 |
55,4 / 74,2 |
55,4 / 74,2 |
|||||||||||||||
2300 rpm |
18,4 / 24,7 |
42,8 / 57,4 |
41,5 / 55,6 |
41,5 / 55,6 |
- |
55,4 / 74,2 |
55,4 / 74,2 |
55,4 / 74,2 |
|||||||||||||||
1800 rpm |
18,4 / 24,7 |
35,4 / 47,4 |
35,4 / 47,4 |
35,4 / 47,4 |
- |
45,7 / 61,2 |
45,4 / 61,2 |
45,4 / 61,2 |
|||||||||||||||
1500 rpm |
18,4 / 24,7 |
28,6 / 38,3 |
28,6 / 38,3 |
28,6 / 38,3 |
- |
37,4 / 50,1 |
37,4 / 50,1 |
37,4 / 50,1 |
|||||||||||||||
Blocked ISO fuel stop power (IFN) for intermittent load according to ISO 3046-1. Applies to constant speed. |
3000 rpm |
- |
43,6 / 58,4 |
- |
- |
- |
55,4 / 74,2 |
- |
- |
||||||||||||||
1800 rpm |
- |
31,3 / 41,9 |
- |
31,3 / 41,9 |
- |
41,0 / 55,0 |
41,0 / 55,0 |
- |
|||||||||||||||
1500 rpm |
- |
25,5 / 34,2 |
- |
25,5 / 34,2 |
- |
35,0 / 46,9 |
35,0 / 46,9 |
- |
|||||||||||||||
Blocked ISO fuel stop power (IFNsi) for strongly intermit- tent load according to ISO 3046-1 |
2800 rpm |
- |
43,7 / 58,6 |
43,6 / 58,4 |
48,2 / 64,6 |
- |
- |
- |
63,7 / 85,4 |
||||||||||||||
2300 rpm |
- |
42,8 / 57,4 |
42,5 / 57,0 |
47,5 / 63,7 |
- |
- |
- |
62,2 / 83,3 |
|||||||||||||||
1800 rpm |
- |
38,2 / 51,2 |
38,2 / 51,2 |
38,2 / 51,2 |
- |
- |
- |
50,2 / 67,3 |
|||||||||||||||
1500 rpm |
- |
29,3 / 39,3 |
29,3 / 39,3 |
31,4 / 42,1 |
- |
- |
- |
41,1 / 55,1 |
|||||||||||||||
Blocked ISO standard power (ICFN; not overloadable) according to ISO 3046-1. Applies to variable speed and constant load. Note: Not available as power rating. |
3000 rpm |
- |
- |
- |
39,8 / 53,3 |
- |
49,9 / 66,9 |
- |
49,5 / 66,3 |
||||||||||||||
2800 rpm |
18,4 / 24,7 |
39,2 / 52,5 |
39,2 / 52,5 |
39,2 / 52,5 |
- |
49,9 / 66,9 |
49,9 / 66,9 |
49,9 / 66,9 |
|||||||||||||||
2300 rpm |
18,4 / 24,7 |
37,4 / 50,1 |
37,4 / 50,1 |
37,4 / 50,1 |
- |
49,9 / 66,9 |
49,9 / 66,9 |
49,9 / 66,9 |
|||||||||||||||
1800 rpm |
18,4 / 24,7 |
31,9 / 42,7 |
31,9 / 42,7 |
31,9 / 42,7 |
18,4 / 24,7 |
41,1 / 55,1 |
41,3 / 54,3 |
41,3 / 54,3 |
|||||||||||||||
1500 rpm |
18,4 / 24,7 |
25,7 / 34,4 |
25,7 / 34,4 |
25,7 / 34,4 |
18,4 / 24,7 |
33,7 / 45,2 |
33,7 / 45,2 |
33,7 / 45,2 |
|||||||||||||||
Blocked ISO standard power (ICFN; not overloadable) according to ISO 3046-1. Applies to constant speed and constant load (e. g. generators) |
3000 rpm |
- |
- |
- |
- |
- |
49,9 / 66,9 |
- |
49,9 / 66,9 |
||||||||||||||
1800 rpm |
18,4 / 24,7 |
- |
- |
28,5 / 38,2 |
18,4 / 24,7 |
36,4 / 48,8 |
36,4 / 48,8 |
36,4 / 48,8 |
|||||||||||||||
1500 rpm |
18,4 / 24,7 |
- |
- |
22,6 / 30,3 |
18,4 / 24,7 |
31,0 / 41,6 |
31,0 / 41,5 |
31,0 / 41,5 |
Note :
- (i) Available as of 2024
- (ii) Including engine mounted aftertreatment
- Abbreviations ICFN / IFN: I = ISO Standard (3046); C = Continuous; F = Fuel stop power; N = Net power.
- ICFN: Continuous service: rated output available 1/1 h. Unlimited h/year service time at a load factor of 100%.
- IFN: Intermittent service: rated output available 1/6 h. Unlimited h/year service time at load factor of 80%.