HATZ - Industrial diesel engine - H Series

Hatz H-series: innovation meets reliability
A groundbreaking downsizing approach was adopted in the development of the Hatz H-series. The outcome are extremely compact, turbocharged engines that reach a maximum output of 64 kilowatts, setting benchmarks in their performance classes
.
Type  
4 - Stroke liquid-cooled diesel engine
Aspiration  
Turbo without
charge air cooling
Turbocharger with charge air cooling
Natural aspiration
Turbocharger with charge air cooling
Number of cylinders  
3
3
3
3
4
4
4
4
Bore and stroke mm
84 x 88
Displacement cc
1454
1962
Compression ratio  
17,5:1
Fuel  
Diesel fuel (ASTM No. 2-D)
Engine oil capacity (Max) l
5,00
9,00
7,00
Dry weight basic engine kg
132
140
154 (ii)
133
159
158
173 (ii)
152
Condition
R.P.M.
Engine output max (kW / hp)
Blocked ISO fuel stop power (IFN) for intermittent loading according to ISO 3046-1.6
Applies to variable speed. 3H50TICD | 3H50TIC
Also available with 36.4 kW /
49.4 hp @ 2500 rpm for use in California without registration requirements.
3000 rpm
-
-
-
44,2 / 59,2
-
55,4 / 74,2
-
55,0 / 73,7
2800 rpm
18,4 / 24,7
43,7 / 59,6
43,6 / 58,4
43,6 / 58,4
-
55,4 / 74,2
55,4 / 74,2
55,4 / 74,2
2300 rpm
18,4 / 24,7
42,8 / 57,4
41,5 / 55,6
41,5 / 55,6
-
55,4 / 74,2
55,4 / 74,2
55,4 / 74,2
1800 rpm
18,4 / 24,7
35,4 / 47,4
35,4 / 47,4
35,4 / 47,4
-
45,7 / 61,2
45,4 / 61,2
45,4 / 61,2
1500 rpm
18,4 / 24,7
28,6 / 38,3
28,6 / 38,3
28,6 / 38,3
-
37,4 / 50,1
37,4 / 50,1
37,4 / 50,1
Blocked ISO fuel stop power (IFN) for intermittent load according to ISO 3046-1.
Applies to constant speed.
3000 rpm
-
43,6 / 58,4
-
-
-
55,4 / 74,2
-
-
1800 rpm
-
31,3 / 41,9
-
31,3 / 41,9
-
41,0 / 55,0
41,0 / 55,0
-
1500 rpm
-
25,5 / 34,2
-
25,5 / 34,2
-
35,0 / 46,9
35,0 / 46,9
-
Blocked ISO fuel stop power
(IFNsi) for strongly intermit-
tent load according to
ISO 3046-1
2800 rpm
-
43,7 / 58,6
43,6 / 58,4
48,2 / 64,6
-
-
-
63,7 / 85,4
2300 rpm
-
42,8 / 57,4
42,5 / 57,0
47,5 / 63,7
-
-
-
62,2 / 83,3
1800 rpm
-
38,2 / 51,2
38,2 / 51,2
38,2 / 51,2
-
-
-
50,2 / 67,3
1500 rpm
-
29,3 / 39,3
29,3 / 39,3
31,4 / 42,1
-
-
-
41,1 / 55,1
Blocked ISO standard power (ICFN; not overloadable) according to ISO 3046-1.
Applies to variable speed and constant load.
Note: Not available as power rating.
3000 rpm
-
-
-
39,8 / 53,3
-
49,9 / 66,9
-
49,5 / 66,3
2800 rpm
18,4 / 24,7
39,2 / 52,5
39,2 / 52,5
39,2 / 52,5
-
49,9 / 66,9
49,9 / 66,9
49,9 / 66,9
2300 rpm
18,4 / 24,7
37,4 / 50,1
37,4 / 50,1
37,4 / 50,1
-
49,9 / 66,9
49,9 / 66,9
49,9 / 66,9
1800 rpm
18,4 / 24,7
31,9 / 42,7
31,9 / 42,7
31,9 / 42,7
18,4 / 24,7
41,1 / 55,1
41,3 / 54,3
41,3 / 54,3
1500 rpm
18,4 / 24,7
25,7 / 34,4
25,7 / 34,4
25,7 / 34,4
18,4 / 24,7
33,7 / 45,2
33,7 / 45,2
33,7 / 45,2
Blocked ISO standard power (ICFN; not overloadable) according to ISO 3046-1.
Applies to constant speed and constant load
(e. g. generators)
3000 rpm
-
-
-
-
-
49,9 / 66,9
-
49,9 / 66,9
1800 rpm
18,4 / 24,7
-
-
28,5 / 38,2
18,4 / 24,7
36,4 / 48,8
36,4 / 48,8
36,4 / 48,8
1500 rpm
18,4 / 24,7
-
-
22,6 / 30,3
18,4 / 24,7
31,0 / 41,6
31,0 / 41,5
31,0 / 41,5

Note :

  • (i) Available as of 2024
  • (ii) Including engine mounted aftertreatment
  • Abbreviations ICFN / IFN:  I = ISO Standard (3046); C = Continuous; F = Fuel stop power; N = Net power.
  • ICFN: Continuous service: rated output available 1/1 h. Unlimited h/year service time at a load factor of 100%.
  • IFN: Intermittent service: rated output available 1/6 h. Unlimited h/year service time at load factor of 80%.